Features |
PMDX-411 |
PMDX-414 |
PMDX-416 |
PMDX-424 |
PMDX-410 |
PMDX-412 |
PMDX-422 |
production status |
active |
active
|
active |
active |
legacy*
now use
PMDX-414
|
legacy*
now use
PMDX-414
|
legacy* |
host connection |
USB-A plug pigtail |
USB-B jack |
USB-B jack |
USB-B jack, electrically isolated |
USB-B jack |
USB-B jack |
USB-B jack |
signal connections on pluggable 0.150" screw terminal blocks |
no, DB-25 male only |
yes |
yes |
yes |
only for encoder |
yes |
yes |
ribbon header for remote DB-25 |
no, direct mounted DB-25 male only |
yes |
yes, for motor drivers only |
yes, for motor drivers only |
yes
|
yes |
yes |
Motor outputs, 16 mA buffered for step and direction |
4 axes |
4 axes |
4 axes |
4 axes with support for 5th motor in tandem mode |
4 axes
|
4 axes |
4 axes |
Selectable "common" for step and direction signals
on terminal blocks |
no, always uses ground common on DB-25 male |
yes, selectable via plug-in software |
yes, selectable via plug-in software |
yes, selectable via plug-in software |
yes, via jumper |
yes, selectable via plug-in software |
yes, via jumper |
|
PMDX-411 |
PMDX-414 |
PMDX-416 |
PMDX-424 |
PMDX-410 |
PMDX-412 |
PMDX-422 |
Status inputs, including E-Stop with support
for contact closures, 5 volt logic signals, or NPN sensors |
5 buffered |
5 buffered and filtered |
5 Opto-isolated |
9 Opto-isolated, +12 unregulated power available for proximity
sensors |
5 buffered and filtered |
5 buffered and filtered |
5 buffered and filtered |
Aux or Encoder inputs, 3 buffered and filtered signals for
one encoder with A, B, and Index,
or 3 Aux signals |
none |
buffered and filtered, +5 power available |
buffered and filtered, +5 power available |
buffered and filtered, +5 power available |
buffered and filtered, +5 power available |
none |
buffered and filtered, +5 power available |
Control signal outputs,16 mA buffered 5 volt logic level |
4 |
4 |
4 |
3 |
4 |
4 |
3 |
Control relay, SPDT 6 ampere 240 VAC relay with MOV to
protect N/O contacts from inductive loads |
none |
none |
1 |
1 |
none |
none |
1 |
PMDX-407 spindle control support |
no |
yes |
yes |
yes |
yes |
yes |
yes |
|
PMDX-411 |
PMDX-414 |
PMDX-416 |
PMDX-424 |
PMDX-410 |
PMDX-412 |
PMDX-422 |
LED's |
2 status (externally visible) |
power, outputs enabled, steps activity, 2 status (externally
visible) |
power, outputs enabled, relay, steps activity, 2 status
(externally visible) |
power, outputs enabled, relay, steps activity, 2 status
(externally visible) |
power, outputs enabled, 2 status (externally visible) |
power, outputs enabled, steps activity, 2 status (externally
visible) |
power, outputs enabled, 2 status (externally visible) |
PWM output available |
yes |
yes |
yes |
yes |
yes |
yes |
yes |
Charge Pump Support |
yes |
yes |
yes |
not applicable |
yes |
yes |
yes |
other features |
entire unit packaged inside a DB-25 male connector shell |
comes with dress plate and board brackets for direct mount
behind a panel |
comes with dress plate and board brackets for direct mount
behind a panel, /Fault input |
ribbon header for future inputs motherboard, support for
PMDX-179 external status panel, /Fault input |
n/a |
comes with dress plate and board brackets for direct mount
behind a panel |
n/a |
Power requirements |
USB powered |
USB powered |
USB powered |
100 to 250 VAC, 50/60 Hz or 24 VDC option |
USB powered |
USB powered |
USB powered
|
*Legacy products are still supported and will continue to get plug-in updates because they share the same plug-in as active